G-711 Sterilizable pH Electrode - Country of origin US |
Manufacturer, Exporter, Wholesaler and Supplier of Automation and Instrumentation Products such as Sterilizable pH Electrode and our setup is situated in Pune, Maharashtra, India.
These models have a permanently installed cable and cannot be autoclaved.Typically used in steel vessels in cheesestarter tanks for the dairy industry, this robust design withstands multiple SIP and CIP cycles, and holds up best under the wash-down conditions since there is no external connector at the electrode head.Steam Sterilizable.
Standard style G-711 Sterilizable pH electrode is designed to be used in bioprocess applications where CIP/SIP procedures are used. Built to withstand repeated steam sterilization cycles, the FermProbe quickly stabilizes after steam exposure to be back on-line in half the time of other electrodes. This rugged, low impedance, Sterilizable pH electrode continues to provide fast and precise pH measurements even after harsh use and prolonged steam exposure.
|
|
|
|
|
|
STANDARD PH ELECTRODES
The G-711 Sterilizable pH electrode is designed for economy while still retaining all performance
specifications. This electrode is secured into the housing with a reusable electrode retainer nut. All
housings are shipped with a reusable electrode retainer nut to be used with this style.
Features of the G-711 Sterilizable pH Electrode
• Most economical, cost effective design.
• Secures to housing with reusable retainer nut.
• Rubber strain relief minimizes cable fatigue.
• Available only with integral cable. |
|
|
SPECIFICATION
PH Electrode Specifications
• 0 – 13 pH range
• Steam Sterilizable to 135° C
• 150 psig max. pressure
• Double junction, Ag-AgCl reference system
• Electrode secures to housing with threaded retainer nut
CONFIRM CABLE LENGTH AND CONNECTOR
Model G-711 pH electrodes come with 15 Ft cable and BNC connector. If you need a different
cable length or connector, please call the Sales Department for more information.
ORDERING INFORMATION
Model G-711 pH with Integral Cable
Electrode
Model |
Class |
Electrode
Length |
Cable
Length |
Connector
|
Electrode Part Number
|
G-711 |
C |
130 mm |
15Ft |
BNC |
G-711-C130-B15BC |
• Dimensions “X”- 130mm
• Dimensions “Y”- 152mm
G-746 Autoclavable pH Electrode
The G-746 style can be used in either bench top or production vessels and is available in a variety of lengths.Steam Sterilizable and Autoclavable.
This is the standard MSSet metric connector. This style has been used as a standard for years. It is designed to be used in bioprocess applications where CIP/SIP procedures are used. The G-746 Autoclavable pH Electrode will withstand multiple autoclaving or sterilization cycles, however, an autoclave cap should be used when autoclaving the electrode.
METRIC FERMPROBE G-746 AUTOCLAVABLE PH ELECTRODE
This Autoclavable pH electrode style features a metric Pg13.5 threaded polymer cap that allows it to be used with European style electrode housings. Autoclavable as well as steam Sterilizable, this style of pH is the first choice for use with small Autoclavable bench top vessels. Available only in the disconnect cap style. Cables must be ordered separately (see the Accessories tab for compatible cables).
FEATURES
• Metric threaded cap is compatible with nearly all European designed bioprocess electrode housings.
• Steam Sterilizable and Autoclavable.
• First choice for use with small Autoclavable vessels.
• Double junction, Ag-AgCl reference system
• Available in variety of lengths for different insertion length requirements and applications.
SPECIFICATION
• 0 – 13 pH range
• Steam Sterilizable to 135° C
• 150 psig max. pressure
• Double junction, Ag-AgCl reference system
• Metric Pg13.5 threaded disconnect cap
ORDERING INFORMATION
Model G-746 pH FermProbe with Standard Metric Cap
Electrode
Model |
Use with these Housing Models or
Bench top vessel sizes |
Electrode
Length |
Cable
Length |
Connector
|
Electrode Part Number
|
G-746 |
325, 335 Class D
<1L Vessel |
120 mm |
Order |
Separately |
G-746 -B120-DH |
|
Note: the vessel sizes are for guidance only – check your own vessel dimensions or the length of the electrode you are replacing.
RECOMMENDED HOUSINGS
The G- 746 pH Electrode has a metric Pg13.5 threaded polymer cap allowing it to be used with European style housings. We would recommend the following MSSet sensor housings for use with the Model G- 746 FermProbe® steam Sterilizable and Autoclavable pH electrode: Model 335 Unguarded Sensor Housing – Standard 25mm (Pg 13.5), typical vessel insertion lengths 52mm & 120mm.
COMPATIBLE CABLES
The F-635 Autoclavable pH Electrode uses a standard S8 detachable cable connection. We recommend
the following cables for use with it:
Cable Typel |
Sensor Connector & Device Connector |
Device Terminal |
HP Plug to BNC Plug, Type A |
|
|
HP Plug to BNC Plug, Type M |
|
|
HP Plug to DIN Plug, Type M |
|
|
HP Plug to Crimped Ferrules, Type M
|
|
|
HP Plug to Ferrules, Solution
Ground, Type N |
|
|
ADDITIONAL INFORMATION : |
Application |
Bioprocess |
Cap / Connector |
Pg13.5, S8 |
Connection Type / Size |
Pg13.5 |
Features |
Autoclavable, Steam Sterilizable |
Installation |
In-Line |
Measurement |
pH |
Regulatory |
FDA Compliant |
Size / Type |
12 mm |
|
|
T521 pH/ORP Sensors 3/4" Threads & Recessed Bulb
• Built-in temperature compensation
• Built-in solution ground
• Custom cable lengths
• Choice of cable connectors
APPLICATION
In-Line & Submersion
MAXIMUM FLOW RATE
10 ft (3 m) per second
CHEMICAL-RESISTANT WETTED MATERIALS
These high quality sensors are constructed of corrosion-resistant wetted materials including
Ryton, Teflon and glass.
COAXIAL POROUS TEFLON REFERENCE JUNCTION
The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.
SPECIFICATION
• PH Range: 0-14 pH
• Redox Range: ± 5000 mV
• Temp Range: 0 -105º C
• Max Pressure/Temp: 150 psig at 100º C
• Reference: Ag-AgCl
• Wetted Materials: Ryton, Teflon & Glass
• Standard cable length: 5 meters (15 Ft)
ORDERING INFORMATION
T511 pH/ORP Sensors 3/4″ Threads & Guard
• Built-in temperature compensation
• Built-in solution ground
• Custom cable lengths
• Choice of cable connectors
APPLICATION
In-Line & Submersion
MAXIMUM FLOW RATE
3 meters (10 ft) per second
CHEMICAL-RESISTANT WETTED MATERIALS
These high quality sensors are constructed of corrosionresistant wetted materials including Ryton®, Teflon® and glass.
COAXIAL POROUS TEFLON® REFERENCE JUNCTION
The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.
SPECIFICATION
• PH Range: 0-14 pH
• Redox Range: ± 5000 mV
• Temp Range: 0 -105º C
• Max Pressure/Temp: 150 psig at 100º C
• Reference: Ag-AgCll
• Wetted Materials: Ryton, Teflon & Glass
• Standard cable length: 5meters (15 Ft)
ORDERING INFORMATION
|