Electro-Magnetic Flow Meters - MS FL 0117

Manufacturer, Exporter, Wholesaler and Supplier of Automation and Instrumentation Products such as Electro Magnetic Flow Meters and our setup is situated in Pune, Maharashtra, India.

 

DESCRIPTION:

MICROSET series MS FL 0117 are micro-controller based full-bore type electromagnetic Flow Meters specially used for various industrial applications. These Flow Meters accurately measure the flow rate of conductive liquids & slurries in closed pipes. Due to its simple & rigid design, the Flow Meters is an obstruction-less & maintenance-free instrument in place of conventional mechanical flow measuring devices. The use of 'Pulsed DC' technology offers highest ability & better measuring accuracy in the form of electrical signal 4-20 mA DC linearly proportional to volumetric flow. The instrument is based on Faraday's law of electromagnetic induction.

The instrument in the flow tube generates a magnetic field. The fluid flowing through this magnetic field generates a voltage that is proportional to the flow velocity. Corresponding electrical output is provided with respect to measuring flow range.

   
table-1
 
Electro-Magnetic Flow Meters
 
 
SALIENT FEATURE
• Full Bore Type
• Simple & cost effective construction
• Provides wide flow ranges
• Outstanding Accuracy
• Operates over wide ranges of temperature & pressure
• Easy maintenance as no moving parts
• Pulsed DC coil excitation
• Integral grounding










request
 
 

Advantages and Disadvantages:

  • A magnetic Flow Meters provides an unobstructed flow path, with negligible pressure drop due to its pipe
  • The typical accuracy for a magnetic Flow Meters is + 0.5 % of full scale. This is among the best of the various pipe Flow Meters.
  • The effect of fluid viscosity on flow through a magnetic Flow Meters is essentially the same as for flow through the pipe itself.
  • The magnetic Flow Meters can be used for pipe flow measurement of either clean or dirty liquids, including wastewater, corrosive liquids, or slurries.

Disadvantages of Meter:

  • The magnetic Flow Meters is used primarily for liquids. It doesn't work well for measurement of gas, solvents, alcohol etc. flow rate.
  • In order to use a magnetic Flow Meters for measurement of a liquid's flow rate, liquid must be conductive.
Applications:

Electromagnetic Flow Meters can be used for precise flow measurement of all electrically conductive liquids such as slurries, sewage, milk, water and wastewater.

   
Electromagnetic Flow Meters has many applications across many industries

  • Chemical measurement, Water/waste water Treatment
  • Effluent Treatment
  • Building Automation & plant automation
  • Pulp, paper, Food & Beverage
  • Advanced Metering Infrastructure
  • Meter Data Management
  • Automated meter reading
  • Drinking water
  • Flow measurement
  • Public utility
  • Utility sub meter
  • Water conservation
   
Principle of Operation :
   
Electromagnetic Flow Meters
E: Induced Voltage
B: Magnetic Field Strength
D: Inner Diameter of Pipe
V: Average Velocity
C: Constant E BDV/C
   
TECHNICAL SPECIFICATION :
Media : Liquids (Excluding Solvents, alcohol etc.)
Viscosity   : 200 cp max
Conductivity : Minimum 10 μS/cm
Line Size : 15~300 mm NB
Excitation : Pulsed DC coil
Type of Output : 4~20 mA DC
Calibration Range : As per requirement (Factory Calibrated)
Accuracy : ±0.5% FS
Linearity : ±0.5%
Repeatability : ±1%
Process Temperature : 100°C max
Process Pressure : 10 kg/cm2
Material of Construction of Sensor : Hastelloy C / SS 316L / pl. specify
Body : MS/CS SS / PLASTIC
Wetted Parts : TEFLON (PTFE), RUBBER, EBONITE, UPVC
Power Supply : 24VDC-230 VAC, 50Hz ±10%
Power Consumption : <10 VA
Response Time : <100 micro
Temperature Coefficient : ±0.01% /ºC
Transmitter Enclosure : IP 65
Process Connections : Flanged ASA #150
Operating Conditions : Temp 0~55ºC / Humidity 5~95% non-condensing
   
METER SIZE FLOW RATE (m3/Hr) AT DIFFERENT VELOCITY
INCH DN (mm) 0.3 m/s 1.00 m/s 12.00 m/s
1/2" 15 0.1909 0.636 7.634
1" 25 0.5301 1.767 21.20
1 1/2" 40 1.358 4.524 54.28
2" 50 2.121 7.608 84.83
2 1/2" 65 3.584 11.95 143.2
3" 80 5.429 18.90 217.1
4" 100 8.483 28.2 339.2
5" 125 13.26 44.18 530.1
6" 150 19.09 63.62 763.1
8" 200 33.93 113.1 1357
10" 250 53.02 176.7 2120
12" 300 76.35 254.5 3053
14" 350 103.9 364.4 4156
16" 400 135.8 452.4 5428
   
 
   
 
pH Sensors   I   PH Electrode   I   Industrial Dip   I   Industrial pH Sensors   I   Sterilizable pH Sensors   I   Online PH Indicators / Controllers / Transmitters   I   pH Meters   I   
PH Bench Meter With 0.001 Resolution and Stability Indicator   I   Slim pH Meters   I   
Conductivity Sensor   
I   Conductivity Sensors   I   Conductivity Sensor - Industrial Pipeline   I   Conductivity Sensor - Industrial Dip   I   Sanitary Conductivity Sensor   I   Conductivity Indicating Controller Cum Transmitter   I   Conductivity Meter   I   Multi-ranging Conductivity, TDS, NaCl, Temperature Meter   I   Multi - Ranging Conductivity Meter   I   Dissolved Oxygen Sensors   IGalvanic-Maintenance Free DO2 Electrode  I   Polarographic DO2 Electrode   I   MSSet DO Sensor   I   DO ( Dissolved Oxygen ) Meter   I   Dissolved Oxygen Meters   I   Table Top Dissolved Oxygen Meters   I   Portable Dissolved Oxygen Meters   I   Ultrasonic Level Transmitters   I   Electromagnetic Flow Meters   I   pH Transmitters   I   On-line Panel Mounted PH Indicator cum Transmitter   I   Online pH Transmitters   I   Oxidation Reduction Potential   I   Oxidation Reduction Potential Sensor (I) – ( ORP Sensors )   I   Oxidation Reduction Potential Sensor – ( ORP Sensors )   I   Online Oxidation Reduction Potential Indicator, Controller and Transmitter   I  Oxidation Reduction Potential Transmitters - ( ORP Transmitters )   I   Ozone Amperometric Sensors   I   Dissolved Chlorine Sensors   I  TDS Indicating Controller   I   Magnetic Flowmeter   I   Dissolved Chlorine Dioxide Sensors   I   Dissolved Oxygen Transmitter - ( DO Transmitter )   I   Conductivity Transmitters MS-CT-211T  II  Temperature And Air Velociy Transmitters DUW 221  II   Clamp On Ultrasonic Flow Meters  II   Process Conductivity / TDS Controllers & Transmitter  II   MS Controller Bsed Conductivity Indicators / Controller  II   Electromagnetic Flow Meters MS FL 0117  II   High Precision Air / Gas Velocity Transmitter  II   Magnetic Float Operaded, Guided Level Switch  II   MS Controller Based Conductivity / TDS  II   MS controller Based PH Indicator / Controller  II   MS Controller Based ORP Indicatorsc / Controller  II   Digital pH Indicator CUM Transmitter  II   MS Controller Based pH Meters MS pH 644  II   Digital Bench Top pH Meters  II   Digital Bench Top TDS / Conductivity Meter  II   MS Controller Based TDS Indicators / Contorller  II   UPVc Electromagnetic Flow Meters MS FL 0117  I   Home   I   About Us   I   Contact Us   I