T511 pH/ORP Sensors 3/4″ Threads & Guard

• Built-in temperature compensation
• Built-in solution ground
• Custom cable lengths
• Choice of cable connectors

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 
 

APPLICATION

In-Line & Submersion

MAXIMUM FLOW RATE

3 meters (10 ft) per second

CHEMICAL-RESISTANT WETTED MATERIALS

These high quality sensors are constructed of corrosionresistant wetted materials including Ryton®, Teflon® and glass.

COAXIAL POROUS TEFLON® REFERENCE JUNCTION

The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.

SPECIFICATION

PH Range: 0-14 pH                           
Redox Range: ± 5000 mV                       
Temp Range: 0 -105º C        
Max Pressure/Temp: 150 psig at 100º C
Reference: Ag-AgCll
Wetted Materials: Ryton, Teflon & Glass
Standard cable length: 5meters (15 Ft)

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 

ORDERING INFORMATION

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 
table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 
 

T521 pH/ORP Sensors 3/4" Threads & Recessed Bulb

• Built-in temperature compensation
• Built-in solution ground
• Custom cable lengths
• Choice of cable connectors

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 

 

APPLICATION

In-Line & Submersion

MAXIMUM FLOW RATE

10 ft (3 m) per second

CHEMICAL-RESISTANT WETTED MATERIALS

These high quality sensors are constructed of corrosion-resistant wetted materials including
Ryton, Teflon and glass.

COAXIAL POROUS TEFLON REFERENCE JUNCTION

The large annular junction resists fouling. Also, the sealed, double-junction reference electrode is highly resistant to poisoning.

SPECIFICATION

PH Range: 0-14 pH                           
Redox Range: ± 5000 mV                         
Temp Range: 0 -105º C        
Max Pressure/Temp: 150 psig at 100º C
Reference: Ag-AgCl
Wetted Materials: Ryton, Teflon & Glass
Standard cable length: 5 meters (15 Ft)

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 

ORDERING INFORMATION

table-1
 
pH Electrode for Continuous Flow-thru Monitoring MS 2113/5
 
 

 

 

 

 

 
pH Sensors   I   PH Electrode   I   Industrial Dip   I   Industrial pH Sensors   I   Sterilizable pH Sensors   I   Online PH Indicators / Controllers / Transmitters   I   pH Meters   I   
PH Bench Meter With 0.001 Resolution and Stability Indicator   I   Slim pH Meters   I   
Conductivity Sensor   
I   Conductivity Sensors   I   Conductivity Sensor - Industrial Pipeline   I   Conductivity Sensor - Industrial Dip   I   Sanitary Conductivity Sensor   I   Conductivity Indicating Controller Cum Transmitter   I   Conductivity Meter   I   Multi-ranging Conductivity, TDS, NaCl, Temperature Meter   I   Multi - Ranging Conductivity Meter   I   Dissolved Oxygen Sensors   IGalvanic-Maintenance Free DO2 Electrode  I   Polarographic DO2 Electrode   I   MSSet DO Sensor   I   DO ( Dissolved Oxygen ) Meter   I   Dissolved Oxygen Meters   I   Table Top Dissolved Oxygen Meters   I   Portable Dissolved Oxygen Meters   I   Ultrasonic Level Transmitters   I   Electromagnetic Flow Meters   I   pH Transmitters   I   On-line Panel Mounted PH Indicator cum Transmitter   I   Online pH Transmitters   I   Oxidation Reduction Potential   I   Oxidation Reduction Potential Sensor (I) – ( ORP Sensors )   I   Oxidation Reduction Potential Sensor – ( ORP Sensors )   I   Online Oxidation Reduction Potential Indicator, Controller and Transmitter   I  Oxidation Reduction Potential Transmitters - ( ORP Transmitters )   I   Ozone Amperometric Sensors   I   Dissolved Chlorine Sensors   I  TDS Indicating Controller   I   Magnetic Flowmeter   I   Dissolved Chlorine Dioxide Sensors   I   Dissolved Oxygen Transmitter - ( DO Transmitter )   I   Conductivity Transmitters MS-CT-211T  II  Temperature And Air Velociy Transmitters DUW 221  II   Clamp On Ultrasonic Flow Meters  II   Process Conductivity / TDS Controllers & Transmitter  II   MS Controller Bsed Conductivity Indicators / Controller  II   Electromagnetic Flow Meters MS FL 0117  II   High Precision Air / Gas Velocity Transmitter  II   Magnetic Float Operaded, Guided Level Switch  II   MS Controller Based Conductivity / TDS  II   MS controller Based PH Indicator / Controller  II   MS Controller Based ORP Indicatorsc / Controller  II   Digital pH Indicator CUM Transmitter  II   MS Controller Based pH Meters MS pH 644  II   Digital Bench Top pH Meters  II   Digital Bench Top TDS / Conductivity Meter  II   MS Controller Based TDS Indicators / Contorller  II   UPVc Electromagnetic Flow Meters MS FL 0117  I   Home   I   About Us   I   Contact Us   I
Enquiry   I   Sitemap