• 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 20
11 22 33 44 55 66 77 88 99 1010 1111 1212 1313 1414 1515 1616 1717 1818 1919 2020 2120
 

Dissolved Oxygen Transmitter

 
Dissolved Oxygen Transmitter
 
 

Salient Features :
• On-Line measurement.
• 2 wire system.
• 4-20 mA DC output.
• Auto / Manual temperature compensation.
• On-Line indication through LCD display.
• Flame-proof, IP-65, llA, llB CMRI certified housing.






 

Description
MicroSet series are dissolved oxygen transmitter used for various industrial applications. It can accept input from DO2 electrode the signal is transmitted in the form of electrical 4-20 mA signal. The on-line indication is provided through LCD. Span / Zero adjustment are easily accessible

 

Technical Specifications
Type of Input : From DO2 Electrode
Type of Output: 4-20 mA DC, 2 wire Isolated
Display: 8 x 1 LCD
Calibration Range: Factory Calibrated
Temperature Compensation: Auto / Manual through RTD, Pt 100 sensor for 0-100oC
Accuracy: +/- 1% F. S.
Isolation: 1.4 KV between Input, Output & Power Supply
Power Supply: 24 V DC, External
Power Consumption: < 50 mW
Response Time: < 500 mSec
Temperature Coefficient: +/- 0.01% peroC
Enclosure: Flame-proof, IP-65, llA, llB CMRI Certified
Dimensions: 135 (H) x 182 (W) including cable gland x 170 (D) in mm approx.
Process Connections: 3 / 4”  ET
Mounting: 2” Pipe Mounting
Weight: 1 kg
Operating Conditions: Temperature 0 to 55oC / Humidity 5 to 95 % non condensing

 
 

 

DISSOLVED OXYGEN TRANSMITTER Micro-DO 211T
 
Dissolved Oxygen Transmitter
 
 

Salient Features :
• Online Measurement
• 2 wire System.
• 4-20mA DC Output.
• Auto/ Manual Temperature Compensation.
• Simple Operating interface with basic pictographs.
• Easy installation with per Assembly empty Enclosure & Plug in terminal.
• Online Indication through LCD Displa.y
• Protection Class IP- 65.

 


Description
MicroSet series Micro- DO 211T are dissolved oxygen transmitters used for various industrial applications. It can accept input from DO electrode the signal is transmitted in the form of electrical 4 - 20 mA signal. The online indication is provided through LCD. Span/Zero adjustments are easily accessible.

Technical Specifications
Type of Input: From DO Electrode (Galvanic/Poloragrahic)
Type of Output: 4 - 20 mA DC, 2 wire Isolated
Display: COG Display 128 X 64
Calibration Range: Factory Calibrated
0 Temperature Compensation: Auto / Manual through RTD, Pt 100 sensor for 0-150˚C
Accuracy: +/- 1% F. S.
Isolation: 1.4 KV between Input, Output & Power Supply
Power Supply: 24 V DC, External
Power Consumption: < 50 mW
Response Time: < 500 mSec
0 Temperature Coefficients: +/- 0.01% per ˚C
Enclosure: IP-65
Dimensions: 135 (H) x 182 (W) including cable gland x 170 (D) in mm approx.
Electrical Connections: 3/4” ET
Mounting: 2” Pipe Mounting
Weight: 1 kg
Operating Conditions: Temperature -20 to 75˚C / Humidity 5 to 95% non condensing
Storage Temperature: -22 to 176˚F (-30 to 80˚C)
Housing: Cast Aluminium with epoxy coating NEMA 4X (IP-65)
Digital Communication: HART

DIMENSIONAL & MOUNTING DETAILS:
POWER SUPPLY VS LOAD GRAPH LOOP DIAGRAM

 

 

 

 
PH Sensor   I   PH Electrode   I   Industrial Dip   I   Industrial PH Sensor   I   Sterilizable PH Sensor   I   Online PH Indicator / Controller / Transmitter   I   PH Meter   I   
PH Bench Meter With 0.001 Resolution and Stability Indicator   I   Slim PH Meter   I   
Conductivity Sensor   
I   Conductivity Sensors   I   Conductivity Sensor - Industrial Pipeline   I   Conductivity Sensor - Industrial Dip   I   Sanitary Conductivity Sensor   I   Conductivity Indicating Controller Cum Transmitter   I   Conductivity Meter   I   Multi-ranging Conductivity, TDS, NaCl, Temperature Meter   I   Multi - Ranging Conductivity Meter   I   Dissolved Oxygen Sensors   IGalvanic-Maintenance Free DO2 Electrode  I   Polarographic DO2 Electrode   I   MicroSet DO Sensor   I   DO ( Dissolved Oxygen ) Meter   I   Dissolved Oxygen Meter   I   Table Top Dissolved Oxygen Meter   I   Portable Dissolved Oxygen Meter   I   Ultrasonic Level Transmitter   I   Electromagnetic Flow Meter   I   PH Transmitters   I   On-line Panel Mounted PH Indicator cum Transmitter   I   Online PH Transmitter   I   Oxidation Reduction Potential   I   Oxidation Reduction Potential Sensor (I) – ( ORP Sensor )   I   Oxidation Reduction Potential Sensor – ( ORP Sensor )   I   Online Oxidation Reduction Potential Indicator, Controller and Transmitter   I  Oxidation Reduction Potential Transmitters - ( ORP Transmitters )   I   Ozone Amperometric Sensors   I   Dissolved Chlorine Sensors   I  TDS Indicating Controller   I   Magnetic Flowmeter   I   Dissolved Chlorine Dioxide Sensors   I   Dissolved Oxygen Transmitter - ( DO Transmitter )   I   Conductivity Transmitter Micro-CT-211T  II  Temperature and Air Velociy Transmitter DUW 221  II   Clamp On Ultrasonic Flow Meter  II   Process Conductivity / TDS Controller & Transmitter  II   Micro Controller Bsed Conductivity Indicator / Controller  II   Electromagnetic Flow Meter MS FL 0117  II   High Precision Air / Gas Velocity Transmitter  II   Magnetic Float Operaded, Guided Level Switch  II   Micro Controller Based Conductivity / TDS  II   Micro controller Based PH Indicator / Controller  II   Micro Controller Based ORP Indicatorc / Controller  II   Digital pH Indicator CUM Transmitter  II   Micro Controller Based PH Meter MS pH 644  II   Digital Bench Top pH Meter  II   Digital Bench Top TDS / Conductivity Meter  II   Micro Controller Based TDS Indicator / Contorller  II   UPVc Electromagnetic Flow Meter MS FL 0117  I   Home   I   About Us   I   Contact Us   I
Enquiry   I   Sitemap